The experts in water heaters and heat pumps have combined the technology of both to bring you a very clever solution – a Hot Water Heat Pump called HydraHeat®. Using the efficiency of heat pump technology, HydraHeat® will heat a home’s water while saving you up to 75% on your water heating costs*. The result is a far more cost-effective and more sustainable solution for the homes of tomorrow.

This energy-efficient hot water heat pump is eligible for an NZ Green Energy Loan.

The HydraHeat® head unit has been designed and built right here in New Zealand for Kiwi conditions, and the whole system is easy to install for any home.

Description

Product Details

Energy Savings
Up to 75% Energy Savings *
Provides highly efficient water heating, minimising energy consumption and lowering operating costs.
Sustainability
Dedicated to Sustainability **
Powered by only 150g (nominal charge) of high-efficiency R290 refrigerant with low Global Warming Potential and COP of 4.7.
Renowned Quality
Renowned Quality
Crafted with exceptional quality by Rinnai New Zealand, the trusted name in total home living.
NZ Made
HydraHeat® Designed & Built in NZ
Specifically designed for New Zealand climatic conditions (from -10°C to +42°C), as well as coastal locations. Operates in full heat pump mode right down to -10°C without the need for electric boosting.
Reliability
Reliability
The inbuilt electric element guarantees a consistent and dependable supply of hot water, at all times.
Modular Design
Modular ‘Heat Pump Ready’ Design +
Upgrade from a standalone HydraHeat® electric cylinder to Hot Water Heat Pump Technology by adding the HydraHeat® head unit.

+ If not planning to upgrade to Hot Water Heat Pump Technology, the recommendation is to purchase a standard Rinnai cylinder best suited to your requirements.
Easy Servicing
Easy Servicing
Removable Heat Pump unit allows for easy servicing, and ensures uninterrupted supply of hot water.
Frost Protection
Frost Protection
Built-in defrost and frost protection functions to handle colder climates.
MEPS Compliant
NZ MEPS Compliant
MEPS (Minimum Energy Performance Standard) means less heat loss from unit and less energy use, resulting in a more efficient product. Not all Hot Water Heat Pumps in New Zealand are MEPS compliant.
Warranties
Warranties
5-year heat pump unit warranty and a 7-year cylinder warranty.
Interface
User Friendly Control Interface
Features OLED screen and six operation modes for versatility.
Modes
6 Operation Modes
Standard, Boost, Eco 55, Eco 50, High Usage, and Element Only.
Residential Styles
Ideal for Various Residential Styles
The 275L is suitable for homes of 2-5 people and the 340L is suitable for 2-7 people. Plus an operating sound level of only 45dB(A) makes it suitable for a wide range of homes, including built-up residential areas.

* When a comparison calculation is made to a 250L standard electric hot water cylinder when heating water from 19°C to 55 °C.

** Coefficient of Performance was measured at the following conditions: Inlet water temperature 19°C, Outlet Water temperature 55°C, Dry Bulb Temperature 19°C.

Product Description

The Rinnai HydraHeat® is designed primarily for outdoor installations. It may be possible to install internally if the proposed location is not an occupied space as defined by AS/NZS 5149, consult a qualified installer prior to installation.

Scope of Use

Primarily designed for residential applications.

Not suitable as a spa or swimming pool heater. Not suitable for hydronic or for in-series installation in ring main systems*.

Hard and acidic water will need to be treated to use this product, refer water quality parameters in the support material (downloads).

*Refer installation guide within the downloads tab for further details.

Technical Specifications

Model number / order code 275L – RHPN361A275E20
340L – RHPN361A340E20
Storage capacity 275 L & 340 L
COP 4.7 W/W
(inlet water temp 19 ºC, outlet water temp. 55 ºC, ambient temp. 19 ºC)

Accredited Testing to AS/NZS 5125 by NATA accredited Provider.
Rated heat pump input / output 802 W / 3725 W

In standard, eco 50/55 modes, the heat pump provides 100% of the heating within the operating range. Outside these limits the electric element will operate.

Hot water recovery rate 89 L/h

Recovery rate is calculated at Eco 55 mode, 19 ºC ambient temp., 36 ºC rise.
Cylinder element rating 2 kW
Cylinder construction Enamel
Colour Dune

Bunnings colour match for cylinder (for touchups):

  • Base Dulux Vivid White
  • Can size 0.25
  • M OY7.75, EE OY8.25, G 0Y2.75
Head unit data label position Positioned on the divider panel between the fan and compressor—to the right of the control panel.
Operating temperature -10 to 42 ºC
Noise level 45 dB(A)

Sound pressure level measured at 1 m distance from the water heater in a free field. Appliance operated in standard mode (60 ºC) at an ambient temperature of 19 ºC.
Refrigerant type R290 / 150 g (nominal charge)
Modes of operation
  • Standard (factory preset): water stored at 60 ºC
  • Boost: one off electric boost to 70 ºC
  • Eco 55: water stored at 55 ºC
  • Eco 50: water stored at 50 ºC
  • High usage: water stored at 70 ºC (heat pump + electric element)
  • Element only: heat pump turned off, electric element heats water to 70 ºC
  • Shutdown: in standby, heat pump and electric element are turned off
Dimensions
  • Assembled: 275L – height 1750 mm, Ø692 mm | 340L – height 1995 mm, Ø692 mm
  • Heat pump header: Height 510 mm
Water supply and connections
  • Mains pressure hot water cylinder
  • Min. inlet water pressure – 100 kPa
  • TPR (supplied) – 850 kPa
  • Cold water expansion valve – 700 kPa
  • Pressure limiting valve – 500 kPa
Weights
  • Heat pump header: 36.4 kg (net), packaged 45 kg
  • Full system: 275 L approx. 388 kg | 340 L approx. 465 kg
IP rating IPX4 header and cylinder
Market release 275L: Nov 2023
340L: Oct 2024
MasterSpec link MasterSpec Partner