Balanced Pressure Heat Recovery Ventilation Solutions
Lossnay by Mitsubishi Electric, is an advanced Fresh Air Heat Recovery Ventilation System that captures and filters fresh outdoor air (as opposed to attic air) to replace indoor stale air for an all-round healthier, drier and warmer home. But what makes Lossnay so different from other ventilation systems is our patented Heat Exchanger, which is the secret to the heat recovery capabilities of the Lossnay ventilation unit and provides several important benefits.

The Mitsubishi Electric Lossnay Difference
-
- Draws in fresh air from the outside not the attic
- Removes stale air from the inside
- Circulates fresh air without draughts
- Heat recovery from stale outgoing air
- Efficient heat recovery from damp areas
- Whisper quiet operation from 14dB
- Balanced Pressure Ventilation
- Designed for modern homes that are more airtight
What makes the Balanced Pressure Lossnay VL220 Heat Recovery Home Ventilation System from Mitsubishi Electric so different from other systems is our advanced Diamond Lossnay Core at the heart of the heat exchanger.

The patented highly efficient Diamond Core is designed to maximise heat recovery from both stale outgoing air as well as heat energy contained in warm damp air from areas such as bathrooms, toilets and kitchens.

The available energy is absorbed and re-used to provide pre-warming in winter or pre-cooling in summer, rather than going to waste by directly transferring this air outside. In doing so, moisture build up in your home is minimised while healthy humidity levels are maintained and managed.

The end result: your home is ventilated with fresh, filtered and clean pre-warmed (or cooled) air at the same time whilst maintaining optimum humidity levels for healthy living. The system is super energy efficient and designed specifically to be whisper quiet.
Why Outside Air, Not Attic Air?
Not all air is created equal. Lossnay only draws fresh air from the outside – it does not draw air from the attic. The absence of significant air movement common in attics means the air is likely to be stale. In addition, build-up of dust, dirt and other contaminants such as mould, insect and rodent droppings makes this air much harder to filter before it is distributed through your home. This is why the Balanced Pressure Lossnay System specifically utilises direct fresh air instead.

How does Lossnay work?
Watch an example of a Lossnay Ventilation System
Key Features

Improved Air Quality
TBy drawing in fresh outdoor air, indoor air quality is improved as high levels of CO2, odours and other pollutants are removed from your home.

Creates a Healthier Home
Filtered fresh air improves air quality for allergy and asthma sufferers.

Fresh Air Without Windows Open
Lossnay allows you to have a well-ventilated home without the need to open windows. This improves the safety of your home and family meaning outdoor noise is minimised.

Assists Moisture and Condensation Control
Lossnay effectively reduces moisture in your home by directly removing stale air that causes condensation via the Lossnay Core

Retains Heat
Lossnay’s unique Heat Recovery Technology collects up to 86% of the heat energy in outgoing air which is then used to pre-warm or cool the fresh air vented in.

Energy Efficient
Incoming fresh air is pre-warmed so your heating system isn’t required to work as hard to reach desired temperature. This is highly energy efficient, and can help reduce heating bills.

Balanced Pressure, No Draughts
Lossnay is specifically designed for more airtight homes built to the current New Zealand building code, bringing in the optimum amount of fresh air without creating draughts and minimising indoor temperature fluctuations.

Quietest in its Class
At an ultra quiet 14dBA in low fan speed, the Lossnay VL220 is the quietest system in its class.

Easy To Clean
The standard filters can be removed for regular cleaning to keep the unit in optimal working condition.

Easy Control At Your Finger Tips
An intuitive wall controller with easy to read LCD display comes standard. Fan speed, night set back and 24-hour and weekly timers can easily be customised and programmed with up to 8 stop and start patterns per day.
Dimension

VL-220CZGV-E
Dimensions and Installation Example
VL-220CZGV-E
Additional information
| Controller Type | Advanced Wi-Fi Control, Wireless Controller |
|---|
VL-220CZGV-E – Lossnay Balanced Pressure Fresh Air Energy Recovery Home Ventilation
| Heat exchange system: Heat Recovery Ventilating System | |||
| Heat exchange element material: Non-permeable specially coated resin core | |||
| Dimensions (WxDxH, mm): 850 x 720 x 320 | |||
| Weight: 31 kg | |||
| Duct size: 100mm – 125mm – 150mm | |||
| Power Supply: 230V +/- 10% / Single Phase / 50 Hz | |||
| Heat Recovery Ventilation Mode | |||
| Running Current (Fan 1-4): 0.11A – 0.18A – 0.29A – 0.60A | |||
| Input Power (Fan 1-4): 8.5 – 18.5 – 35 – 80 W | |||
| Air Volume (Fan 1-4): 18 – 33 – 46 – 64 L/s | |||
| External Static Pressure (Fan 1-4): 13 – 44 – 84 – 164 Pa | |||
| Temperature exchange efficiency (Fan 1-4): 86.0 – 85.0 – 84.0 – 82.0 % | |||
| Noise (Fan Speed 1-4): 14 – 19 – 25 – 31 dBA | |||
| Bypass Mode | |||
| Running Current (Fan 1-4): 0.12A – 0.19A – 0.30A – 0.61A | |||
| Input Power (Fan 1-4): 11.1 – 21.3 – 37.8 – 82.8 W | |||
| Air Volume (Fan 1-4): 18 – 33 – 46 – 61 l/s | |||
| External Static Pressure (Fan 1-4): 11 – 40 – 75 – 150 Pa | |||
| Noise (Fan 1-4): 14 – 19 – 25 – 31 dBA | |||
| Notes | |||
| *: Noise dB, (measured at 1.5m under panel) | |||
| **: Lossnay Ventilation Complies with Standards: S/NZS60335.2.80 and AS/NZS CISPR14.1 | |||
Warrenty
5 year parts and labour warranty. For full details view warranty terms and conditions.pdf (199 KB)
Related Products
Mitsubishi AP35 Smart High Wall Heat Pump
The AP35 Smart High Wall Heat Pump sets the new benchmark for energy-efficient heating and cooling, featuring built-in Wi-Fi Energy Monitoring for total control over your power use. Starting at a whisper quiet 19dBa, the AP35 is ideal for living rooms and bedrooms! With Dual Barrier Coating that prevents dust and dirt build-up on the inner surface, the AP35 Smart stays clean year-round; maximising efficiency and home comfort.
Cooling
Capacity
3.5 kW
Heating
Capacity
3.7 kW
Mitsubishi AP80 Classic High Wall Heat Pump
The AP80 Classic High Wall Heat Pump sets a new standard in super energy efficient heating and cooling. With Dual Barrier Coating that prevents dust and dirt build-up on the inner surface, the AP80 Classic stays clean year-round; maximising efficiency and home comfort.
Cooling
Capacity
7.8 kW
Heating
Capacity
9.0 kW
Mitsubishi Ducted PEAD 50 Heat Pump
The thin, low-profile, ceiling-concealed PEAD 50 are the perfect answer for air conditioning requirements of buildings with minimum ceiling installation space and wide-ranging external static pressure. Energy-saving efficiency has been improved, thereby reducing electricity consumption and contributing to further reductions in operating cost.
Cooling
Capacity
5.0 kW
Heating
Capacity
6.0 kW
Mitsubishi GS25 Standard High Wall Heat Pump
The GS25 Standard High Wall Heat Pump offers real value and sets a new benchmark in super energy efficient heating and cooling. Next-generation EcoCore Technology is designed to use less power than ever before, and because they are very quiet, they are ideal where it matters most – in living rooms and bedrooms!
Cooling
Capacity
2.5 kW
Heating
Capacity
3.1 kW
Mitsubishi GS35 Standard High Wall Heat Pump
The GS35 Standard High Wall Heat Pump offers real value and sets a new benchmark in super energy efficient heating and cooling. Next-generation EcoCore Technology is designed to use less power than ever before, and because they are very quiet, they are ideal where it matters most – in living rooms and bedrooms!
Cooling
Capacity
3.5 kW
Heating
Capacity
3.7 kW