The GS25 Standard High Wall Heat Pump offers real value and sets a new benchmark in super energy efficient heating and cooling. Next-generation EcoCore Technology is designed to use less power than ever before, and because they are very quiet, they are ideal where it matters most – in living rooms and bedrooms!


Cooling
Capacity

2.5 kW

Heating
Capacity

3.1 kW

Description

 

R32

Next Generation R32 Inverter Technology

Superior energy efficiency is achieved by incorporating a large, high-density heat exchanger, an advanced high-efficiency fan motor and a next-generation inverter compressor.

Blue Fin

Blue Fin Outdoor Coil Protection

Slows the corrosion process on the heat exchanger caused by salt and sulphur, making it ideal for coastal and high sulphur areas.

Filtration

Filtration for Cleaner Air

Traps dust and allergens. The optional Anti-Allergy Enzyme Filter effectively breaks down harmful microbes like bacteria and mould.

Econo Cool

Econo Cool

Maximises energy efficient cooling by automatically switching to Swing Mode to create a refreshing cooling breeze effect.

Swing Vane

Vertical Swing Vane Airflow

Adjust airflow direction up, down, or set to Swing Mode to ensure every corner of the room stays comfortable.

12hr Controller

12 Hour Programmable Controller

Simplified control with an easy-to-read display and large buttons, focusing on the functions that matter most.

PAR Controller

Optional Deluxe PAR Weekly Controller

Program up to four time and temperature settings for each day of the week to maximise energy efficiency.

Wi-Fi

Optional Wi-Fi Control Upgrade

Pre-heat or cool your room from anywhere using your smartphone. Arrive home to total comfort every time.

Plasma Quad

Optional Plasma Quad Connect

Advanced air filtration module that cleans and minimises dust and allergens for better indoor air quality.

Additional information

Controller Type

Advanced Wi-Fi Control, Wireless Controller

MSZ-GS25VFD-A1 // GS25 Standard High Wall Heat Pump System

Function: Cooling/Heating Type: Single Split, Inverter
Rated
Capacity – Cooling: 2.5 kW Capacity – Heating: 3.1 kW
Capacity – Cooling (min. – max.): 1.1 – 3.0 kW Capacity – Heating (min. – max.): 1.3 – 3.8 kW
Power Input – Cooling: 0.59 kW Power Input – Heating: 0.78 kW
Current – Cooling [In+Outdoor] (Rated): 2.80 A Current – Heating [In+Outdoor] (Rated): 3.70 A
Energy Rating Residential
ZERL – Cooling (Cold/Mixed/Hot): 2.5 / 2.5 / 3.0 ZERL – Heating (Cold/Mixed/Hot): 2.0 / 2.5 / 3.0
TCSPF (Cold/Mixed/Hot): 4.13 / 4.17 / 4.76 HSPF (Cold/Mixed/Hot): 3.75 / 4.19 / 4.60
EER / COP: 4.24 / 3.97 AEER / ACOP: 4.12 / 3.89
Energy Rating Commercial
TCSPF (Cold/Mixed/Hot): 5.13 / 4.93 / 5.09 HSPF (Cold/Mixed/Hot): 3.97 / 4.35 / 4.60
Performance
Operation Range – Cooling: -10 / +46 degC Operation Range – Heating: -15 / +24 degC

 

MSZ-GS25VFD-A2 – R32 Wall Mounted Indoor Unit – White

Function: Cooling/Heating Type: Single Split, Inverter
Nominal Capacity
Capacity – Cooling: 2.5 kW Capacity – Heating: 3.1 kW
Sound Level – Cooling (Low – Super High, dB(A)): 22 / 30 / 37 / 44 Sound Level – Heating (Low – Super High, dB(A)): 23 / 30 / 37 / 44
Air Volume – Cooling (Super High, Litre/sec): 163 Air Volume – Heating (Super High, Litre/sec): 172
Refrigerant: R32 Liquid pipe size (OD, mm): 6.35
Gas pipe size (OD, mm): 9.52 Max. pipe length (m): 20
Max. pipe height (m): 12 Power supply: 230V / Single Phase / 50/60 Hz
Dimensions (WxDxH, mm): 799 x 232 x 290 Weight: 8.5 kg

 

MUZ-GS25VFD-A2 – R32 Inverter Outdoor Unit

Function: Cooling/Heating Type: Single Split, Standard Inverter
Operation Range – Cooling: -10 / +46 degC Operation Range – Heating: -15 / +24 degC
Sound Level – Cooling (dB(A)): 47 Sound Level – Heating (dB(A)): 48
Air Volume – Cooling (Litre/sec): 577 Air Volume – Heating (Litre/sec): 483
Power supply: 230V / Single Phase / 50 Hz Refrigerant: R32
Liquid pipe size (OD, mm): 6.35 Gas pipe size (OD, mm): 9.52
Max. pipe length (m): 20 Max. pipe height (m): 12
Dimensions (WxDxH, mm): 800 x 285 x 550 Weight: 28 kg

 

· Rating Conditions (AS / NZS 3823):
Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB. Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

· Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

· Dry function will not work when the room temperature is below 13°C.

· Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

· Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

· Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
EER = Energy Efficiency Ratio
COP = Coefficient of Performance
AEER# = Annual Energy Efficiency Ratio
ACOP# = Annual Coefficient of Performance
#These include standby power in the rating calculation

· Star Ratings based on the Seasonal Energy Rating standard for New Zealand – cold zone [GEMS 2019]

Warrenty

5 year parts and labour warranty. For full details view warranty terms and conditions.pdf (199 KB)